Rat Cytochrome CP450 (Cytochrome C P450) ELISA Kit

Rat Cytochrome CP450 (Cytochrome C P450) ELISA Kit

principle

This experiment uses the double antibody sandwich ABC-ELISA method. The anti-rat Cytochrome C P450 monoclonal antibody was coated on the enzyme plate, the standard and sample Cytochrome C P450 were combined with the monoclonal antibody, and the biotinylated anti-rat Cytochrome C P450 was added to form an immune complex and connected to the plate On the top, the horseradish peroxidase-labeled Streptavidin is combined with biotin, the substrate working solution is added, the blue is added, and finally the stop solution sulfuric acid is added, and the OD value is measured at 450nm. Draw a standard curve to find the concentration of Cytochrome C P450 in the specimen.

Kit composition (stored at 2-8 ° C)

Coated Wells

96 wells

Enzyme Conjugate

12ml

10 × Sample Buffer

12ml

20 × concentrated washing solution (Wash Buffer)

50ml

Standards (Standards): 20ng / bottle

2 bottles

Substrate working solution (TMB Solution)

12ml

The first antibody working solution (Biotinylated Antibody)

12ml

Stop Solution (Stop Solution)

12ml

Prepare reagents and collect blood samples

1. Collect specimens: serum, plasma (EDTA), cell culture supernatant, tissue homogenate, etc., as soon as possible, stored at 2-8 ℃ for 48 hours; longer time must be frozen (-20 ℃ or -70 ℃) to avoid Repeated freezing and thawing.

2. Preparation of standard solution: add 1ml of distilled water to mix well before use to make a 20ng / ml solution. Set 8 standard tubes, add 900ul of sample dilution in the first tube, and 500ul of sample dilution in the second to eighth tubes. Add 100 ul of 20 ng / ml standard solution to the first tube and mix it. Then aspirate 500 ul with the sampler and move to the second tube. Repeat the dilution in this manner repeatedly, draw 500ul from the seventh tube and discard it. The eighth tube is a blank control.

3. The 10 × specimen dilution is diluted 1:10 with distilled water (example: 1ml concentrated dilution + 9ml distilled water).

4. Washing solution: 1:20 dilution with redistilled water (example: 1ml concentrated washing solution is added with 19ml of redistilled water)

Testing procedures

1. Add sample: add 100ul of standard or sample to be tested to each well, mix the reaction plate thoroughly and place at 37 ℃ for 120 minutes.

2. Wash the plate: wash the reaction plate 4-6 times with the washing solution, and print it on the filter paper.

3. Add 100ul of the first antibody working solution to each well. The reaction plate was mixed thoroughly and then placed at 37 ° C for 60 minutes.

4. Wash board: same as above.

5. Add 100ul of enzyme-labeled antibody working solution to each well. Place the reaction plate at 37 ° C for 30 minutes.

6. Wash board: same as above.

7. Add 100ul of substrate working solution to each well, and place in a dark place at 37 ℃ for 15 minutes.

8. Add 100ul of stop solution to each well and mix well.

9. Measure absorbance at 450nm with a microplate reader within 30 minutes.

Result calculation and judgment

1. All OD values ​​should be calculated after subtracting the blank value.

2. With the standard products 2000, 1000, 500, 250, 125, 62.5, 31.2, 0 pg / ml as the abscissa, and the OD value as the ordinate, draw a graph on the graph paper and draw a standard curve.

3. According to the OD value of the sample, find the corresponding Cytochrome C P450 content on the graph.

Kit performance

1. Sensitivity: The smallest detection concentration of Cytochrome C P450 is less than 15pg / ml.

2. Specificity: can simultaneously detect recombinant or natural rat Cytochrome C P450. Does not cross-react with other cytokines in rats.

3. Repeatability: The coefficient of variation within the board and the board is less than 8.9%.

Precautions

1. The above standard holes and samples to be tested are recommended to be re-holes, and the standard curve should be made at the same time for each measurement.

2. The washing process is critical. Insufficient washing will lead to an increase in accuracy error and OD value.

3. After opening the slats, the remaining slats should be sealed again to keep the slats dry.

4. This kit should be stored in a 4oC refrigerator.

5. This kit is for scientific research only, not for clinical diagnosis!

CE certificates EN71 or American standard ASTM F2264.

Two wheel Child Scooter, three wheel push scooter, four wheel kick board scooter for all children playing.

The Kids Scooter wheel size from 95mm-145mm. Our factory can supply PVC, PU with led lights or not wheels kick scooter.

Steel dirt scooter, aluminum children scooter, even aluminum deck or others steel foot scooter.

We can OEM or ODM for you. Welcome to contact us, let`s go on our cooperation and friendship.

Kids Kick Scooter

Kids Kick Scooter,Complete Scooter,Kids Scooter,Child Scooter,Baby Scooter

YONGKANG YISHANG INDUSTRY&TRADE CO.,LTD. , http://www.yes-trade.com